SIMATIC S7-1500 Compact CPU CPU 1512C-1 PN, central processing unit with working memory 250 KB for program and 1 MB for data, 32 digital inputs, 32 digital outputs, 5 analog inputs, 2 analog outputs, 6 high speed counters, 4 high speed outputs for PTO/PWM/frequency output 1. interface: PROFINET IRT with 2 port switch, 48 NS bit-performance, incl. front connector push-in, SIMATIC memory card necessary

 

 

 

 

General information
Product type designationCPU 1512C-1 PN
HW functional statusFS03
Firmware versionV2.9
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeYes; With minimum OB 6x cycle of 625 µs (distributed)
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7512-1CK00-0AB0
Configuration control
via datasetYes
Display
Screen diagonal [cm]3.45 cm
Control elements
Number of keys8
Mode buttons2
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V; 20.4 V DC, for supplying the digital inputs/outputs
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
● Mains/voltage failure stored energy time5 ms; Refers to the power supply on the CPU section
● Repeat rate, min.1/s
Input current
Current consumption (rated value)0.8 A; Without load; 18.8 A: CPU + load
Current consumption, max.1 A; Without load; 19 A: CPU + load
Inrush current, max.1.9 A; Rated value
I²t0.34 A²·s
Digital inputs
● from load voltage L+ (without load), max.20 mA; per group
Digital outputs
● from load voltage L+, max.30 mA; Per group, without load
output voltage / header
Rated value (DC)24 V
Encoder supply
Number of outputs2; One common 24 V encoder supply per 16 digital inputs
24 V encoder supply
● 24 VYes; L+ (-0.8 V)
● Short-circuit protectionYes
● Output current, max.1 A
Power
Infeed power to the backplane bus10 W
Power consumption from the backplane bus (balanced)9 W
Power loss
Power loss, typ.15.2 W
Memory
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
● integrated (for program)250 kbyte
● integrated (for data)1 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
● maintenance-freeYes
CPU processing times
for bit operations, typ.48 ns
for word operations, typ.58 ns
for fixed point arithmetic, typ.77 ns
for floating point arithmetic, typ.307 ns
CPU-blocks
Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max.1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range0 ... 65 535
● Size, max.250 kbyte
FC
● Number range0 ... 65 535
● Size, max.250 kbyte
OB
● Size, max.250 kbyte
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of isochronous mode OBs1
● Number of technology synchronous alarm OBs2
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
Nesting depth
● per priority class24
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
IEC counter
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 times
● Number2 048
Retentivity
— adjustableYes
IEC timer
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Extended retentive data area (incl. timers, counters, flags), max.1 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Size, max.16 kbyte
● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustableYes
● Retentivity presetNo
Local data
● per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules2 048; max. number of modules / submodules
I/O address area
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
● Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● Via CM6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated1
● Via CM6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max.32; CPU + 31 modules
● Number of lines, max.1
PtP CM
● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
● Number16
Clock synchronization
● supportedYes
● in AS, masterYes
● in AS, deviceYes
● on Ethernet via NTPYes
Digital inputs
integrated channels (DI)32
Digital inputs, parameterizableYes
Source/sink inputP-reading
Input characteristic curve in accordance with IEC 61131, type 3Yes
Digital input functions, parameterizable
● Gate start/stopYes
● CaptureYes
● SynchronizationYes
Input voltage
● Type of input voltageDC
● Rated value (DC)24 V
● for signal "0"-3 to +5V
● for signal "1"+11 to +30V
Input current
● for signal "1", typ.2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizableYes; none / 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms
— at "0" to "1", min.4 µs; for parameterization "none"
— at "0" to "1", max.20 ms
— at "1" to "0", min.4 µs; for parameterization "none"
— at "1" to "0", max.20 ms
for interrupt inputs
— parameterizableYes; Same as for standard inputs
for technological functions
— parameterizableYes; Same as for standard inputs
Cable length
● shielded, max.1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 100 kHz
● unshielded, max.600 m; for technological functions: No
Digital outputs
Type of digital outputTransistor
integrated channels (DO)32
Current-sourcingYes; Push-pull output
Short-circuit protectionYes; electronic/thermal
● Response threshold, typ.1.6 A with standard output, 0.5 A with high-speed output; see manual for details
Limitation of inductive shutdown voltage toConnector X11: -0.8 V; connector X12: L+ (-53 V)
Controlling a digital inputYes
Accuracy of pulse durationUp to ±100 ppm ±2 μs at high-speed output; see manual for details
minimum pulse duration2 µs; With High Speed output
Digital output functions, parameterizable
● Switching tripped by comparison valuesYes; As output signal of a high-speed counter
● PWM outputYes
— Number, max.4
— Cycle duration, parameterizableYes
— ON period, min.0 %
— ON period, max.100 %
— Resolution of the duty cycle0.0036 %; For S7 analog format, min. 40 ns
● Frequency outputYes
Switching capacity of the outputs
● with resistive load, max.0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output; see manual for details
● on lamp load, max.5 W; 1 W with high-speed output, i.e. when using a high-speed output; see manual for details
Load resistance range
● lower limit48 Ω; 240 ohms with high-speed output, i.e. when using a high-speed output; see manual for details
● upper limit12 kΩ
Output voltage
● Type of output voltageDC
● for signal "0", max.1 V; With high-speed output, i.e. when using a high-speed output; see manual for details
● for signal "1", min.23.2 V; L+ (-0.8 V)
Output current
● for signal "1" rated value0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details
● for signal "1" permissible range, min.2 mA
● for signal "1" permissible range, max.0.6 A; 0.12 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details
● for signal "0" residual current, max.0.5 mA
Output delay with resistive load
● "0" to "1", max.200 µs
● "1" to "0", max.500 µs; Load-dependent
for technological functions
— "0" to "1", max.5 µs; Depending on the output used, see additional description in manual
— "1" to "0", max.5 µs; Depending on the output used, see additional description in manual
Parallel switching of two outputs
● for logic linksYes; for technological functions: No
● for upratingNo
● for redundant control of a loadYes; for technological functions: No
Switching frequency
● with resistive load, max.100 kHz; For high-speed output, 100 Hz for standard output
● with inductive load, max.0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve
● on lamp load, max.10 Hz
Total current of the outputs
● Current per channel, max.0.5 A; see additional description in the manual
● Current per group, max.8 A; see additional description in the manual
● Current per power supply, max.4 A; 2 power supplies for each group, current per power supply max. 4 A, see additional description in manual
for technological functions
— Current per channel, max.0.5 A; see additional description in the manual
Relay outputs
● Number of relay outputs0
Cable length
● shielded, max.1 000 m; 600 m for technological functions; depending on output frequency, load, and cable quality; max. 50 m at 100 kHz
● unshielded, max.600 m; for technological functions: No
Analog inputs
Number of analog inputs5; 4x for U/I, 1x for R/RTD
● For current measurement4; max.
● For voltage measurement4; max.
● For resistance/resistance thermometer measurement1
permissible input voltage for voltage input (destruction limit), max.28.8 V
permissible input current for current input (destruction limit), max.40 mA
Cycle time (all channels), min.1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual
Technical unit for temperature measurement adjustableYes; °C/°F/K
Input ranges (rated values), voltages
● 0 to +10 VYes; Physical measuring range: ± 10 V
— Input resistance (0 to 10 V)100 kΩ
● 1 V to 5 VYes; Physical measuring range: ± 10 V
— Input resistance (1 V to 5 V)100 kΩ
● -10 V to +10 VYes
— Input resistance (-10 V to +10 V)100 kΩ
● -5 V to +5 VYes; Physical measuring range: ± 10 V
— Input resistance (-5 V to +5 V)100 kΩ
Input ranges (rated values), currents
● 0 to 20 mAYes; Physical measuring range: ± 20 mA
— Input resistance (0 to 20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
● -20 mA to +20 mAYes
— Input resistance (-20 mA to +20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
● 4 mA to 20 mAYes; Physical measuring range: ± 20 mA
— Input resistance (4 mA to 20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
Input ranges (rated values), resistance thermometer
● Ni 100Yes; Standard/climate
— Input resistance (Ni 100)10 MΩ
● Pt 100Yes; Standard/climate
— Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohmsYes; Physical measuring range: 0 ... 600 ohms
— Input resistance (0 to 150 ohms)10 MΩ
● 0 to 300 ohmsYes; Physical measuring range: 0 ... 600 ohms
— Input resistance (0 to 300 ohms)10 MΩ
● 0 to 600 ohmsYes
— Input resistance (0 to 600 ohms)10 MΩ
Cable length
● shielded, max.800 m; for U/I, 200 m for R/RTD
Analog outputs
integrated channels (AO)2
Voltage output, short-circuit protectionYes
Cycle time (all channels), min.1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual
Output ranges, voltage
● 0 to 10 VYes
● 1 V to 5 VYes
● -10 V to +10 VYes
Output ranges, current
● 0 to 20 mAYes
● -20 mA to +20 mAYes
● 4 mA to 20 mAYes
Load impedance (in rated range of output)
● with voltage outputs, min.1 kΩ
● with voltage outputs, capacitive load, max.100 nF
● with current outputs, max.500 Ω
● with current outputs, inductive load, max.1 mH
Cable length
● shielded, max.200 m
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.16 bit
● Integration time, parameterizableYes; 2.5 / 16.67 / 20 / 100 ms, acts on all channels
● Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10
Smoothing of measured values
● parameterizableYes
● Step: NoneYes
● Step: lowYes
● Step: MediumYes
● Step: HighYes
Analog value generation for the outputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.16 bit
Settling time
● for resistive load1.5 ms
● for capacitive load2.5 ms
● for inductive load2.5 ms
Encoder
Connection of signal encoders
● for voltage measurementYes
● for current measurement as 4-wire transducerYes
● for resistance measurement with two-wire connectionYes
● for resistance measurement with three-wire connectionYes
● for resistance measurement with four-wire connectionYes
Connectable encoders
● 2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Encoder signals, incremental encoder (asymmetrical)
● Input voltage24 V
● Input frequency, max.100 kHz
● Counting frequency, max.400 kHz; with quadruple evaluation
● Signal filter, parameterizableYes
● Incremental encoder with A/B tracks, 90° phase offsetYes
● Incremental encoder with A/B tracks, 90° phase offset and zero trackYes
● pulse encoderYes
● pulse encoder with directionYes
● pulse encoder with one impulse signal per count directionYes
Errors/accuracies
Linearity error (relative to input range), (+/-)0.1 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, max.-60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.02 %
Linearity error (relative to output range), (+/-)0.15 %
Temperature error (relative to output range), (+/-)0.005 %/K
Crosstalk between the outputs, max.-80 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.05 %
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)0.3 %
● Current, relative to input range, (+/-)0.3 %
● Resistance, relative to input range, (+/-)0.3 %
● Resistance thermometer, relative to input range, (+/-)Pt100 Standard: ±2 K, Pt100 Climate: ±1 K, Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K
● Voltage, relative to output range, (+/-)0.3 %
● Current, relative to output range, (+/-)0.3 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)0.2 %
● Current, relative to input range, (+/-)0.2 %
● Resistance, relative to input range, (+/-)0.2 %
● Resistance thermometer, relative to input range, (+/-)Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K, Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K
● Voltage, relative to output range, (+/-)0.2 %
● Current, relative to output range, (+/-)0.2 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min.30 dB
● Common mode voltage, max.10 V
● Common mode interference, min.60 dB; at 400 Hz: 50 dB
Interfaces
Number of PROFINET interfaces1
1. Interface
Interface types
● RJ 45 (Ethernet)Yes; X1
● Number of ports2
● integrated switchYes
Protocols
● IP protocolYes; IPv4
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● SIMATIC communicationYes
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyYes
PROFINET IO Controller
Services
— PG/OP communicationYes
— Isochronous modeYes
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTYes
— PROFIenergyYes; per user program
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.128; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communicationYes
— Isochronous modeNo
— IRTYes
— PROFIenergyYes; per user program
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
Interface types
RJ 45 (Ethernet)
● 100 MbpsYes
● AutonegotiationYes
● AutocrossingYes
● Industrial Ethernet status LEDYes
Protocols
Number of connections
● Number of connections, max.128; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces88
● Number of S7 routing paths16
Redundancy mode
● H-Sync forwardingYes
Media redundancy
— Media redundancyonly via 1st interface (X1)
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDYes; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC communication
● PG/OP communicationYes; encryption with TLS V1.3 pre-selected
● S7 routingYes
● S7 communication, as serverYes
● S7 communication, as clientYes
● User data per job, max.See online help (S7 communication, user data size)
Open IE communication
● TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
● UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; Max. 5 multicast circuits
● DHCPYes
● DNSYes
● SNMPYes
● DCPYes
● LLDPYes
● EncryptionYes; Optional
Web server
● HTTPYes; Standard and user pages
● HTTPSYes; Standard and user pages
OPC UA
● Runtime license requiredYes; "Small" license required
● OPC UA ClientYes
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of connections, max.4
— Number of nodes of the client interfaces, recommended max.1 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions for session management, per connection, max.1
— Number of simultaneous calls of the client instructions for data access, per connection, max.5
— Number of registerable nodes, max.5 000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)Yes
— Number of sessions, max.32
— Number of accessible variables, max.50 000
— Number of registerable nodes, max.10 000
— Number of subscriptions per session, max.20
— Sampling interval, min.100 ms
— Publishing interval, min.500 ms
— Number of server methods, max.20
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.1 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.1 000
● Alarms and ConditionsYes
— Number of program alarms100
— Number of alarms for system diagnostics50
Further protocols
● MODBUSYes; MODBUS TCP
Isochronous mode
EquidistanceYes
S7 message functions
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.2 500
Number of simultaneously active program alarms 
● Number of program alarms600
● Number of alarms for system diagnostics100
● Number of alarms for motion technology objects80
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 5 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
Status/control
● Status/control variableYes
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max. 
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
● ForcingYes
● Forcing, variablesPeripheral inputs/outputs
● Number of variables, max.200
Diagnostic buffer
● presentYes
● Number of entries, max.1 000
— of which powerfail-proof500
Traces
● Number of configurable Traces4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarmYes
● Hardware interruptYes
Diagnoses
● Monitoring the supply voltageYes
● Wire-breakYes; for analog inputs/outputs, see description in manual
● Short-circuitYes; for analog outputs, see description in manual
● A/B transition error at incremental encoderYes
Diagnostics indication LED
● RUN/STOP LEDYes
● ERROR LEDYes
● MAINT LEDYes
● STOP ACTIVE LEDYes
● Monitoring of the supply voltage (PWR-LED)Yes
● Channel status displayYes
● for channel diagnosticsYes; For analog inputs/outputs
● Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Number of available Motion Control resources for technology objects800
● Required Motion Control resources 
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
● Positioning axis 
— Number of positioning axes at motion control cycle of 4 ms (typical value)5
— Number of positioning axes at motion control cycle of 8 ms (typical value)10
Controller 
● PID_CompactYes; Universal PID controller with integrated optimization
● PID_3StepYes; PID controller with integrated optimization for valves
● PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring 
● High-speed counterYes
Integrated Functions
Counter 
● Number of counters6
● Counting frequency, max.400 kHz; with quadruple evaluation
Counting functions
● Continuous countingYes
● Counter response parameterizableYes
● Hardware gate via digital inputYes
● Software gateYes
● Event-controlled stopYes
● Synchronization via digital inputYes
● Counting range, parameterizableYes
Comparator
— Number of comparators2; per count channel; see manual for details
— Direction dependencyYes
— Can be changed from user programYes
Position detection
● Incremental acquisitionYes
● Suitable for S7-1500 Motion ControlYes
Measuring functions
● Measuring time, parameterizableYes
● Dynamic measurement period adjustmentYes
● Number of thresholds, parameterizable2
Measuring range
— Frequency measurement, min.0.04 Hz
— Frequency measurement, max.400 kHz; with quadruple evaluation
— Cycle duration measurement, min.2.5 µs
— Cycle duration measurement, max.25 s
Accuracy
— Frequency measurement100 ppm; depending on measuring interval and signal evaluation
— Cycle duration measurement100 ppm; depending on measuring interval and signal evaluation
— Velocity measurement100 ppm; depending on measuring interval and signal evaluation
Potential separation
Potential separation digital inputs
● between the channelsNo
● between the channels, in groups of16
Potential separation digital outputs
● between the channelsNo
● between the channels, in groups of16
Potential separation channels
● between the channels and backplane busYes
● Between the channels and load voltage L+No
Isolation
Isolation tested with707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-25 °C; No condensation
● horizontal installation, max.60 °C; note derating data for onboard I/O in the manual. Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
● vertical installation, min.-25 °C; No condensation
● vertical installation, max.40 °C; note derating data for onboard I/O in the manual. Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
● min.-40 °C
● max.70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— GRAPHYes
Know-how protection
● User program protection/password protectionYes
● Copy protectionYes
● Block protectionYes
Access protection
● protection of confidential configuration dataYes
● Password for displayYes
● Protection level: Write protectionYes
● Protection level: Read/write protectionYes
● Protection level: Complete protectionYes
programming / cycle time monitoring / header
● lower limitadjustable minimum cycle time
● upper limitadjustable maximum cycle time
Dimensions
Width110 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.1 360 g
Approvals / Certificates

 

 

 

Etiketler
6ES7512-1CK01-0AB0, 6ES7512-1CK01-0AB0 CPU, 6ES7512-1CK01-0AB0 CPU 1512C-1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog 1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog 1 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog 1 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog 1 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Prog Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB 1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB 1 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB 1 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB 1 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 KB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog 1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog 1 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog 1 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog 1 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Prog Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 1 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 1 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 1 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN 250 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog 1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog 1 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog 1 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog 1 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB Prog Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB 1, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB 1 MB, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB 1 MB Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB 1 Data, 6ES7512-1CK01-0AB0 CPU 1512C-1 PN KB MB,
cultureSettings.RegionId: 0 cultureSettings.LanguageCode: TR
Çerez Kullanımı

Sizlere en iyi alışveriş deneyimini sunabilmek adına sitemizde çerezler(cookies) kullanmaktayız. Detaylı bilgi için sayfamızın footer kısmında sözleşmeler başlığı altında "BEMİRAL ENTEGRE KVKK Kişisel Veri Gizlilik, Saklama, İmha Politikası" ile "KVKK Aydınlatma Metni" ve "Çerez Politikası" dokümanlarını inceleyebilirsiniz.