SIMATIC S7-1500, analog output module AQ8xU/I HS, 16-bit resolution accuracy 0.3%, 8 channels in groups of 8, diagnostics; substitute value 8 channels in 0.125 ms oversampling; the module supports the safety-oriented shutdown of load groups up to SIL2 according to EN IEC 62061:2021 and Category 3 / PL d according to EN ISO 13849-1:2015. delivery including infeed element, shielding bracket and shield terminal: front connector (screw terminals or push-in) to be ordered separately

 

General information
Product type designationAQ 8xU/I HS
HW functional statusfrom FS01
Firmware versionV2.1.0
● FW update possibleYes
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeYes
● Prioritized startupNo
● Output range scalableNo
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV14 / -
● STEP 7 configurable/integrated from versionV5.5 SP3 / -
● PROFIBUS from GSD version/GSD revisionV1.0 / V5.1
● PROFINET from GSD version/GSD revisionV2.3 / -
Operating mode
● OversamplingYes
● MSOYes
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption, max.320 mA; with 19.2 V supply
Power
Power consumption from the backplane bus1.15 W
Power loss
Power loss, typ.7 W
Analog outputs
Number of analog outputs8
Voltage output, short-circuit protectionYes
Voltage output, short-circuit current, max.45 mA
Current output, no-load voltage, max.20 V
Cycle time (all channels), min.125 µs; independent of number of activated channels
Output ranges, voltage
● 0 to 10 VYes
● 1 V to 5 VYes
● -5 V to +5 VNo
● -10 V to +10 VYes
Output ranges, current
● 0 to 20 mAYes
● -20 mA to +20 mAYes
● 4 mA to 20 mAYes
Connection of actuators
● for voltage output two-wire connectionYes
● for voltage output four-wire connectionYes
● for current output two-wire connectionYes
Load impedance (in rated range of output)
● with voltage outputs, min.1 kΩ
● with voltage outputs, capacitive load, max.100 nF
● with current outputs, max.500 Ω
● with current outputs, inductive load, max.1 mH
Cable length
● shielded, max.200 m
Analog value generation for the outputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.16 bit
● Conversion time (per channel)50 µs; independent of number of activated channels
Settling time
● for resistive load30 µs; see additional description in the manual
● for capacitive load100 µs; see additional description in the manual
● for inductive load100 µs; see additional description in the manual
Errors/accuracies
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.02 %
Linearity error (relative to output range), (+/-)0.15 %
Temperature error (relative to output range), (+/-)0.002 %/K
Crosstalk between the outputs, max.-100 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.05 %
note regarding accuracyat temperatures below 0 °C, the figures for operating error and temperature error are doubled
Operational error limit in overall temperature range
● Voltage, relative to output range, (+/-)0.3 %
● Current, relative to output range, (+/-)0.3 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to output range, (+/-)0.2 %
● Current, relative to output range, (+/-)0.2 %
Isochronous mode
Execution and activation time (TCO), min.100 µs
Bus cycle time (TDP), min.250 µs
Interrupts/diagnostics/status information
Diagnostics functionYes
Substitute values connectableYes
Alarms
● Diagnostic alarmYes
Diagnoses
● Monitoring the supply voltageYes
● Wire-breakYes; Only for output type "current"
● Short-circuitYes; Only for output type "voltage"
● Overflow/underflowYes
Diagnostics indication LED
● RUN LEDYes; green LED
● ERROR LEDYes; red LED
● Monitoring of the supply voltage (PWR-LED)Yes; green LED
● Channel status displayYes; green LED
● for channel diagnosticsYes; red LED
● for module diagnosticsYes; red LED
Potential separation
Potential separation channels
● between the channelsNo
● between the channels, in groups of8
● between the channels and backplane busYes
● Between the channels and load voltage L+Yes
Permissible potential difference
between S- and MANA (UCM)8 V DC
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
Suitable for safety-related tripping of standard modulesYes; from FS04
Ecological footprint
● environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]37.6 kg
— global warming potential, (during production) [CO2 eq]11.1 kg
— global warming potential, (during operation) [CO2 eq]26.8 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.364 kg
Highest safety class achievable for safety-related tripping of standard modules
● Performance level according to ISO 13849-1PL d
● Category according to ISO 13849-1Cat. 3
● SIL acc. to IEC 62061SIL 2
● remark on safety-oriented shutdownhttps://support.industry.siemens.com/cs/de/en/view/39198632
product functions / security / header
signed firmware updateNo
data integrityNo
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-30 °C; From FS03
● horizontal installation, max.60 °C
● vertical installation, min.-30 °C; From FS03
● vertical installation, max.40 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Dimensions
Width35 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.325 g
cultureSettings.RegionId: 0 cultureSettings.LanguageCode: TR
Çerez Kullanımı

Sizlere en iyi alışveriş deneyimini sunabilmek adına sitemizde çerezler(cookies) kullanmaktayız. Detaylı bilgi için sayfamızın footer kısmında sözleşmeler başlığı altında "BEMİRAL ENTEGRE KVKK Kişisel Veri Gizlilik, Saklama, İmha Politikası" ile "KVKK Aydınlatma Metni" ve "Çerez Politikası" dokümanlarını inceleyebilirsiniz.